Technical Information

RSSI Radon Certifications:

AT-101 Alpha-track Device Specifications:

  • Manufacturer: RSSI

  • Model number: AT-101

  • Internal chamber volume = 175 mL

  • Track reading area = 159.52 mm2

  • Test duration = 30 days to 1 year (Note: RSSI does not recommend test durations shorter than 30 days. If shorter durations are required, please contact us.)

  • Maximum Minimum Detectable Exposure

    • 10.7 pCi-days/L (397 Bq-days/m3)

  • Maximum Minimum Detectable Concentrations

    • 0.4 pCi/L for 30-day test (13 Bq/m3)

    • 0.1 pCi/L for 90-day test (4 Bq/m3)

  • Typical Minimum Detectable Exposure

    • 6.0 pCi-days/L (178 Bq-days/m3)

  • Typical Minimum Detectable Concentrations

    • 0.2 pCi/L for 30-day test (7 Bq/m3)

    • 0.1 pCi/L for 90-day test (3 Bq/m3)

  • Rounding:

    • < 0.1 pCi/L is rounded to 0.1 pCi/L

    • > 0.1 pCi/L is rounded to one decimal place

    • Bq-days/m3 and Bq/m3 are rounded to the nearest integer

 

AT-102 Alpha-track Device Specifications:

  • Manufacturer: RSSI

  • Model number: AT-102

  • Internal chamber volume = 32 mL

  • Track reading area = 159.52 mm2

  • Test duration = 30 days to 1 year

  • Maximum Minimum Detectable Exposure

    • 18.8 pCi-days/L (695 Bq-days/m3)

  • Maximum Minimum Detectable Concentrations

    • 0.6 pCi/L for 30-day test (23 Bq/m3)

    • 0.2 pCi/L for 90-day test (8 Bq/m3)

  • Typical Minimum Detectable Exposure

    • 10.6 pCi-days/L (390 Bq-days/m3)

  • Typical Minimum Detectable Concentrations

    • 0.4 pCi/L for 30-day test (13 Bq/m3)

    • 0.1 pCi/L for 90-day test (4 Bq/m3)

  • Rounding:

    • < 0.1 pCi/L is rounded to 0.1 pCi/L

    • > 0.1 pCi/L is rounded to one decimal place

    • Bq-days/m3 and Bq/m3 are rounded to the nearest integer

 

< Back to Radon Page  

 

   

 

 


Copyright ©2021 Radiation Safety Services, Inc.

 